Topics & Strategy · Energy & Scope 2

Scope 2 Accounting &
Energy Attribute Assessment

A single site's energy bills, power purchase agreements and certificates can point to different accounting results. A company needs to confirm which consumption should be included, which factor applies to each unit of energy, and which claims the attributes it has procured can support.

Energy & Organizational BoundariesAccounting Methods & EvidenceRule Changes & Data Preparation

Corporate Accounting Context

Even after the energy is bought, emissions figures and usage claims still have to hold up item by item.

When a group consolidates sites across countries, a tenant gets electricity data from a landlord, or a facility generates its own power while also buying and selling electricity, neither bill amounts nor certificate volumes are enough on their own to determine Scope 2 results.

Sustainability, facilities and procurement teams need to align on sites, periods, metering methods and attribute rights before contracts are signed, settled and reported. That reduces the risk of chasing data or buying certificates again at year end.

For example, when a group buys EACs centrally, they still have to be allocated to sites that meet the market and period conditions. When a landlord buys renewable electricity, it also has to be confirmed whether the attributes can be allocated to tenants and their consumption.

Energy & Data Boundaries

First confirm which energy the company uses, then choose the calculation method.

Besides electricity, steam, heating and cooling may also fall under Scope 2. How each site is supplied and how it uses energy determine what data needs to be collected.

  • Organization & Sites

    Start by setting the organizational boundary under the equity share or control approach the company uses. Consumption at leased offices, shared industrial sites and data centers has to be checked against the operating relationship and metering data; who pays the bill does not by itself decide where it belongs.

  • Energy & Flows

    Separate purchased electricity, steam, heating and cooling from the energy produced by the company's own equipment. Record purchased, self-consumed and sold quantities separately. Electricity sold does not directly offset purchased consumption, and upstream fuel and transmission and distribution losses are handled under the applicable scope.

  • Reporting Period & Data Quality

    Align the reporting period, meters and bills. Where meters are shared or data is missing, keep the basis for allocations and estimates. Emission factor updates, site acquisitions or boundary changes also call for a review of year-on-year comparability and whether the base year needs to be recalculated.

Dual Reporting & Emission Factors

One set of energy data, two accounting perspectives.

The location-based method reflects emissions from the grid where energy is used; the market-based method reflects qualifying contractual and energy attribute arrangements. Where dual reporting applies, the two results are disclosed separately. They are not added together or netted against each other, and the lower result is not simply picked.

  • Location-Based Method

    Grid electricity usually takes the average emission factor for the applicable region. Confirm the geographic coverage, data year, units and factor boundary. Buying certificates does not by itself bring the location-based grid factor down to zero.

  • Market-Based Method

    Factors are selected from contractual instruments, supplier data and the applicable data hierarchy, after checking quality criteria. Consumption not covered by qualifying instruments still has to be calculated, using the residual mix or a factor further down the hierarchy as the rules require.

  • How the Difference Informs Decisions

    Break changes in emissions down into the effects of consumption, grid factors and attribute purchases. Lowering market-based results, raising the share of renewable energy used, and supporting additional reductions on the grid each have different measurement and evidence requirements.

If you have operations in markets that offer contractual instruments or supplier-specific data, check your dual reporting obligation under the current Guidance. This assessment is not limited to companies that actively buy renewable electricity.

Attribute & Usage Evidence

Rights acquired by contract have to line up with consumption and claims.

  • Who Holds the Energy Attributes

    PPAs, wheeling contracts and EACs should show who owns the attributes, who the beneficiary is and how retirement is arranged. The same generation attributes cannot be sold twice or claimed by more than one user.

  • Matching Source, Period & Market

    Check the generation period, the consumption period and the applicable market boundary. Cross-border procurement, use across reporting years and supplier-specific factors each need their own check against quality criteria and applicability conditions. Simply holding certificates does not mean every site can use them.

  • Handling Uncovered Consumption

    Reconcile total consumption, eligible attributes and the remaining volume. The residual mix reflects electricity after claimed attributes have been removed. Where no applicable data exists, follow the current hierarchy and disclose the limitation.

Owners of solar PV can also choose to keep or sell the attributes.

Once an owner sells the EACs, it can no longer claim to have used the same renewable energy attributes. Where the power is self-consumed but the attributes are sold, the accounting for that consumption also has to be redone under the Guidance. Asset income and the owner's own targets should be weighed together before the transaction.

EAC Use, Inventory & Sales Management →

Rule Changes & Preparation · Verified as of 2026.09.10

Time and location matching are now being discussed in finer detail.

Current work still rests on the 2015 Scope 2 Guidance and the applicable disclosure rules. Revisions on hourly matching, deliverability and the emission factor hierarchy are not yet final, so companies can start by understanding how their data and contracts will be affected.

  • Issues Under Revision

    The proposals cover time matching between generation and consumption, the conditions for supply to be deliverable to where the energy is used, and the residual mix and other factors. Data estimation, exemptions, existing contracts and transition arrangements are also still under discussion.

  • Latest Published Plan

    The July 2026 plan brings Scope 2 into a consolidated Corporate Standard, with consultation on the consolidated draft expected in Q2 2027 and publication in Q4 2028. This is a development timeline that may change, not a confirmed effective date.

  • What Companies Can Prepare Now

    Understand the time resolution and location information in your meter, load, generation and certificate data. In long-term contracts, leave room for data access and for renegotiating if the rules change, and assess gaps and costs early.

Engagement & Related Work

Keep inventories, procurement and annual data on consistent terms.

Work can start with a single site or a specific contract, sorting out the issues, responsibilities and missing evidence before linking into existing energy planning and annual management.

Accounting judgments and data preparation follow the agreed scope. Third-party verification and final determinations under each disclosure framework rest with the relevant bodies.

Scope 2 Accounting & Energy Attributes

Align energy data with procurement terms.

Bring your site list, consumption data, contracts or existing accounting results, and we'll identify current gaps and the scope of next steps.